Skip to main content

TubaVent®

Balloon Dilation System for Eustachian Tube Dysfunction

Restoring Natural Eustachian Tube Function at its Core

Rhinology Instruments and Disposables for Every Procedure

The TubaVent® Balloon Dilation System by SPIGGLE & THEIS offers a gentle, patient-friendly solution for treating Eustachian Tube Dysfunction. 4.6% of the adult population in the U.S. suffers from Eustachian tube dysfunction (ETD).1 Eustachian Tube Balloon Dilation (ETBD) is the first-line interventional causal treatment of ETD.

Multiple studies have demonstrated that the TubaVent® Balloon Catheter successfully restores normal ear function, leading to high patient satisfaction rates.2,3 Since its launch in 2010 in Europe, TubaVent® has been used in over 150,000 cases worldwide, solidifying its role as a trusted solution for ETD treatment.

The TubaVent® Balloon Dilation System by SPIGGLE & THEIS is available in outer diameter of 3.28 mm and 4.94 mm at 10 atm.

Designed with a unique, low-profile catheter, TubaVent® enhances patient safety without compromising clinical effectiveness - empowering ENT specialists to restore natural function with confidence.

TubaVent® Balloon Dilation System

Specifically designed to treat Eustachian tube dysfunction

  • Two balloon sizes

    3.28 mm and 4.94 mm at 10 atm

  • Semi-compliant balloon
    Allows for fine & precise adjustment
  • Excellent tactile feedback

    During insertion of catheter into Eustachian tube

  • Enhanced protection

    Of the mucosa thanks to olive-shaped tip

  • Proven and trusted system

    TubaVent® has been used in over 150,000 cases since its 2010 launch in Europe


Product Brochure


Quick Reference Guide


Instructions For Use


TubaVent® Specifications

Product Number Technical Details
TubaVent® Short Balloon Catheter 2080-1236320-US Working length 236 mm, balloon 3.28 mm at 10 atm
TubaVent® Short Wide Balloon Catheter 2080-12364520-US Working length 236 mm, balloon 4.94 mm at 10 atm
TubaInsert® ONE 2080-3045-US
 Angled tip 45°
Inflation Device 2080-9030040-US With 50 cm extension tube, syringe volume 30 cc

1Shan A, Ward BK, Goman A.M., et al. (2019) Prevalence of Eustachian Tube Dysfunction in Adults in the United States JAMA Otoaryngology Head Neck Surgery 145, no. 10: 974-975.

2Schröder S, Lehmann M, Ebmeyer J, Upile T, Sudhoff H. Balloon Eustachian tuboplasty: a retrospective cohort study. Clin Otolaryngol. 2015 Dec;40(6):629-38. doi: 10.1111/coa.12429. PMID: 25867023.

3Clinical Affairs SPIGGLE & THEIS Medizintechnik GmbH: Knuth, J. and Warnking, K., Balloon Eustachian Tube Dilatation as the Standard Causal Intervention for Eustachian Tube Dysfunction?! A summary of published clinical research; Whitepaper 2022

Eustachian tube with inflated TubaVent®

TubaVent® short: 3.28 mm at 10 atm
2080-1236320-US

TubaInsert® ONE
2080-3045-US